FAA L-824 Type B Unshielded 5kV

FAA L-824 Type B Unshielded 5kV    

Applications

These cables are used for interconnecting the transformers and the current regulator of airfield lighting systems in series circuits, suitable for fixed applications such as taxiways, runways, navigational aids, and obstruction lighting, can be installed in conduit and direct burial.

Standards

FAA L-824 Type B
ICEA S-96-659/NEMA WC71

Construction

Conductor: Stranded bare or tinned copper conductor.
Insulation: EPR.
Sheath: CPE/PVC.

Technical Data

Rated Voltage Uo/U (Um)

5kV

Maximum Conductor Temperature

90℃

Short Circuit Temperature

250℃

Operating Temperatures

-40℃~+85℃

Minimum Bending Radius

5×OD

Halogen Free

Yes

Abrasion Resistant

Yes

UV Resistant

Yes

Oil Resistant

Yes

Dimensions and Weight

Construction

No. of
Strand

Nominal Insulation
Thickness

Nominal Sheath
Thickness

Nominal Overall
Diameter

Nominal Weight

No. ×mm²/
AWG

-

mm

inches

mm

inches

mm

inches

kg/km

lbs/kft

1×6mm²

7/19

2.3

0.09

1.2

0.05

10.0

0.39

150

101

1×8

7/19

2.3

0.09

0.76

0.03

10.7

0.420

180

121

1×6 7/19 2.3 0.09 0.76 0.03 11.7 0.460 238 160
1×4 7/19 2.3 0.09 0.76 0.03 12.8 0.505 326 219